PortaCount Pro 8030 by TSI - Mask Fit Test System

Personal Monitoring Datalogging
Mask Fit Testing Manufacturer: TSI
PortaCount Pro 8030 by TSI - Mask Fit Test System
Training
Available
PortaCount Pro 8030 by TSI - Mask Fit Test System
PortaCount Pro 8030 by TSI - Mask Fit Test System
Training
TSI PortaCount Troubleshooting Guide: Fix Daily Check Failures & Fit Test Failures
Training
How to Set up a TSI PortaCount Pro 8030 or PortaCount Pro+ 8038

The TSI PortaCount Pro 8030 is a quantitative respirator fit test system compliant with the OSHA-approved fast fit test protocol, reducing test time by 65%. It tests disposable filtering facepieces (Series 100, 99, P3, and HEPA), as well as half and full-face masks, gas masks, PAPR, and SCBA masks.

Click here to verify the right Adapter Kit for your Respirator!

Choose Your Option

Rent for flexible short-term use or purchase to own

Rent
Purchase
Rental Rates
Daily
$240.00
Weekly
$610.00
Monthly
Contact for pricing
Reference rates only. You get the best rate calculation - actual price based on your selected rental dates.
Need Help Choosing?
Our rental specialists can help you select the right equipment for your specific application.
Call 866-736-8347
1
Choose Purchase Option
Rent short-term or buy to own
Required

No rental period selected

Set your dates to see pricing.

Important: These dates apply to your entire cart. Changing dates will affect pricing for all rental items in your cart.
Used Equipment: This equipment has been previously used and tested. It may show signs of wear but is fully functional and inspected.
3
Optional Equipment & Accessories
A Particle Generator choice is required before adding to cart
Choice required
Do you need a Particle Generator? *

The PortaCount needs sufficient ambient particles to run a fit test. In clean indoor air (offices, clinics, hospitals), a particle generator is required to complete tests reliably.

Set the Particle Generator quantity to at least 1 below, or choose "No, I don't need a Particle Generator."

Particle Generator for Respirator Fit Testing Particle Generator for Respirator Fit Testing Loading...

Your Configuration

PortaCount Pro 8030 by TSI - Mask Fit Test System
unit quantity
× $240.00
$240.00 Select dates
Subtotal:
$240.00
Select dates
Technician verified and tested instrumentation before every rental
Expert support available by phone and email
Fast delivery and flexible rental terms

Frequently Asked Questions

It's a quantitative respirator fit test system using CNC technology for OSHA 29 CFR 1910.134-compliant fit testing of tight-fitting respirators — disposable filtering facepieces (Series 100, 99, P3, HEPA), half and full-face masks, gas masks, PAPRs, and SCBA masks. Fit factor range is 1 to >10,000.

Yes — it's ready to use the OSHA-approved fast fit test protocol that reduces test time per worker.

Yes — fit testing with a calibrated quantitative system is a required element of 1910.134 for tight-fitting respirators. Confirm your recordkeeping output format matches your program's documentation requirements.

The PortaCount Pro 8030, alcohol capsule/cartridge, power supply, spare alcohol bottles, zero filters, spare wicks, tubing and adapters, USB cable and flash drive, lanyard, FitPro software and manuals, and calibration certificate.

$240/day and $610/week. Pricing beyond two weeks is by quote. For multi-day fit testing events or programs covering multiple sites, weekly pricing is almost always more economical — most meaningful fit testing campaigns extend beyond a single day.

The 8038 adds specific N95/P2/P1 disposable facepiece support and N95-specific fit factor range (1–200). Choose the 8030 for broad tight-fitting respirator programs without N95 emphasis; choose the 8038 when N95 filtering facepiece testing is central to your program.

Donning issues — strap tension imbalance, hair or skin interference at the seal, and valve seating problems. Correcting the donning procedure typically resolves failures faster than switching equipment or masks.

Features & Capabilities

Calibration Certificate Available: ✓ Yes
Datalogging: ✓ Yes
Monitoring Scope: Personal Monitoring

Equipment Specifications

  • Fit Factor Range: 1 to greater than 10,000
  • Typical Fit Factor Accuracy: ±10% of reading
  • Respirator Facepieces: Full-face elastomeric, Half-face elastomeric, NIOSH series-100, series-99, & series-95 filtering-facepiece
  • Fit Factor Measurement: Direct measurement of fit factor (Cout/Cin)
  • Dimensions: (HWD) 6.75 in. x 8.5 in. x 9.5 in. (17 cm x 22 cm x 24 cm)
  • Weight: Unit Only 5.0 lb. (2.7 kg); With Standard Accessories and Case 16 lb. (7.3 kg)
  • Power: Autosensing 100 to 250 VAC, 50 to 60 Hz
  • Flow Rate: Sample 350 cm3/min; Total 1000 cm3/min (nominal)
  • Temperature Range: Operation 32 to 100°F (0 to 38°C); Storage -40 to 122°F (-40 to 50°C)
  • Alcohol: Hours Per Charge 6 hours at 70°F (21°C); Alcohol Type 99.5%+ reagent-grade isopropyl
  • Carrying Case Dimensions: (HWD) 9 in. x 13.7 in. x 19.5 in. (23 cm x 34.8 cm x 49.5 cm)
  • Pass/Fail Setting: User-selectable: 0 to 10,000
  • Minimum PC Hardware Requirements for FitPro+ Fit Test Software: Windows 7/8/10 (32 and 64 bit); Microsoft .Net version 4; 1 GHz processor; 1280 x 800 screen resolution; 500 MB free disk space; 1 free USB port; CD-ROM reader or internet connection to install software

Kit Contents

8030 PortaCount Pro, Alcohol Capsule & Cartridge, A/C Power Supply, (2) Spare Alcohol Bottles, (2) Zero Filters, (2) Spare Alcohol Wicks, Twin Tube Assembly, 3/16” and 1/4” Tube Adapters, USB A-B Cable and Flash Drive, Lanyard, Calibration Certificate (emailed), Manuals and Software (On Flash Drive)

Ask a Question

Have a question about this product? Fill out the form below and our team will get back to you shortly.

Need Help Choosing the Right Equipment?

Our customer success specialists are here to help you select the perfect equipment for your project