WPF60 FIELD PROBE
WPF60 FIELD PROBE
The Wavecontrol WPF60 isotropic electric field probe measures RF and microwave field strength from 1 MHz to 60 GHz with true RMS detection. It provides 1–1000 V/m (CW) and 1–55 V/m (RMS) measurement ranges with 1 V/m sensitivity and 60 dB dynamic range.
Used to measure electric field strength, power density, and RF exposure levels, this probe is commonly applied in telecommunications site surveys (GSM, 3G, 4G, 5G, Wi-Fi), broadcast and satellite installations, defense and military EMF assessments, and research labs validating RF safety compliance. The WPF60 reaches the highest frequency of the probes we rent, from 1 MHz through millimeter-wave 5G and radar systems.
Common applications: cell sites and broadcast transmitters, 5G mmWave, radar and aerospace, R&D labs, RF heating and drying, diathermy and electrosurgery, and railway communications. See EMF measurement by industry for the standards that apply.
Exposure Hazards This Equipment Detects
Electromagnetic Fields (EMF)
Radio Frequency Radiation (RF)
Equipment Specifications
| Component Role: | Interchangeable field probe for the SMP2/SMP3 EMF meters — determines which field types the meter measures, its frequency coverage and measurement ranges |
| Detection Method / Sensor Type: | Isotropic, true RMS diode technology |
| Measured Parameters: | Electric field (E) |
| Measurement Range: | 1 to 1,000 V/m (CW); 1 to 55 V/m (RMS) |
| Frequency Range: | 1 MHz to 60 GHz |
| Dynamic Range: | 60 dB |
| Resolution: | Sensitivity 1 V/m |
| Accuracy: | Frequency response ±2 dB (2 MHz-17 GHz), ±3 dB (17-40 GHz), ±6 dB (40-60 GHz), -3 dB at 1 MHz. Linearity ±2 dB (1-2 V/m), ±1 dB (2-250 V/m). Isotropic deviation ±1.1 dB below 12 GHz, ±2.2 dB typical 12-60 GHz |
| Additional Features: | 50/60 Hz attenuation >40 dB, eliminating power-line interference. Damage level 1,200 V/m CW. Frequency response can be corrected on the meter using correction factors stored in the probe. Covers the broadest frequency range in the WaveControl lineup, from AM radio through millimetre-wave 5G |
| Calibration Standard: | ISO 17025 accredited (ILAC) |
| Recalibration Interval: | 24 months recommended |
| Compatible Instruments: | WaveControl SMP2, WaveControl SMP3 |
| Operating Temperature Range: | -4°F to 122°F (-20°C to 50°C) |
| Size / Weight: | 28.4 cm x 6 cm dia (11.2 x 2.4 in); 95 g (3.4 oz) |
| Intended Use: | Telecommunications site surveys (GSM, 3G, 4G, 5G, Wi-Fi), broadcast and satellite installations, defence and military EMF assessment, and research labs validating RF safety compliance |
Manufacturer Resources
Documents
Manufacturer documentation is available upon request. Please contact our team for manuals, safety guides, and technical specifications.
Videos
No manufacturer videos are currently available for this product. Check back later or contact us for more information.
Ask a Question
Have a question about this product? Fill out the form below and our team will get back to you shortly.
- Translation missing: en.general.accessibility.refresh_page
- Translation missing: en.general.accessibility.new_window