WATER HAZARD · 6 FIELD PARAMETERS

Water Quality Meters: Rent or Buy

Water hazard monitoring covers the field parameters used to characterize water condition across surface water, groundwater, wastewater, and stormwater. Unlike airborne exposure agents, these fall under the Clean Water Act and Safe Drinking Water Act rather than OSHA exposure limits, and several carry no federal numeric limit at all.

TOP WATER QUALITY RENTAL
YSI ProDSS Multiparameter Digital Water Quality Meter
Water Quality Meter · Area
YSI ProDSS Multiparameter Digital Water Quality Meter
Starting at $235.00 / day

THE INSTRUMENT FOR THESE HAZARDS

Water Quality Meters to Rent

We rent one instrument for water hazards. Its key specifications are below, along with the sensors that decide what it measures.

YSI ProDSS Multiparameter Digital Water Quality Meter
Water Quality Meter
YSI ProDSS Multiparameter Digital Water Quality Meter
Sensor ports
4-port cable assembly accepts any four ProDSS digital smart sensors in any port configuration
Display
Color LCD graphic display, 3.9 x 6.5 cm, with backlit keypad
Data logging
More than 100,000 data sets; single-point or continuous logging
Battery
Rechargeable lithium-ion battery pack; approximately 48 hours (handheld only) or 20 hours (handheld, cable and four sensors); about 9 hours to recharge with the AC adapter
Water rating
IP-67; floats, including with the battery cover off
Operating temperature
0 to 50 °C (32 to 122 °F)
Cable
4-port field cable, 4 meter length. Handheld includes internal GPS.
Size & weight
Instrument 8.3 x 21.6 x 5.6 cm (3.25 x 8.5 x 2.21 in); 567 g (1.25 lb) with batteries

WHAT IT MEASURES

Sensors and what each one reads

Sensor Measures Range Resolution Accuracy Method
Conductivity & Temperature Included626902 ConductivitySalinityTDSTemperature 0 to 200 mS/cm; 0 to 70 ppt salinity; -5 to 70 °C 0.001, 0.01 or 0.1 µS/cm (range dependent); 0.01 ppt salinity; 0.1 °C ±0.5% of reading or 0.001 mS/cm (0 to 100 mS/cm), ±1.0% of reading (100 to 200 mS/cm); ±0.2 °C Four-nickel-electrode cell with integral thermistor
Optical Dissolved Oxygen (ODO) Optional626900 Dissolved oxygen 0 to 50 mg/L; 0 to 500% sat. 0.01 or 0.1 mg/L; 0.1% or 1% sat. (user selectable) ±0.1 mg/L or ±1% of reading (0 to 20 mg/L) Optical luminescence, lifetime method
pH/ORP Optional626904 pHORP 0 to 14 pH; -1999 to 1999 mV 0.01 pH; 0.1 mV ±0.2 pH; ±20 mV Glass bulb combination electrode; platinum button with Ag/AgCl reference
Turbidity Optional626901 TurbidityTSS (correlated) 0 to 4000 FNU 0.1 FNU 0.3 FNU or ±2% of reading (0 to 999 FNU); ±5% of reading (1000 to 4000 FNU) Nephelometric, optical 90° scatter

The conductivity & temperature sensor is fitted to every rental: the meter uses its temperature and salinity readings to compensate the other sensors. Add the optional sensors your job needs. Ranges, resolution and accuracy are the manufacturer's published sensor specifications. Not sure? Talk to our team.

Accessories

PARAMETERS EXPLAINED

What each parameter tells you

Dissolved Oxygen

DO (mg/L, % air saturation)

Dissolved oxygen is the quantity of gaseous oxygen held in solution in water, and it is the single most widely used indicator of aquatic health. Fish, invertebrates and aerobic bacteria all draw oxygen from the water column, and sustained depletion causes stress, kills, and shifts in community structure. Depletion is driven by biological oxygen demand from organic loading, nutrient enrichment and the algal blooms that follow, thermal stratification, and elevated water temperature. Because oxygen solubility falls as temperature and salinity rise, accurate reporting in mg/L depends on measuring temperature and conductivity at the same time.

Regulation, calibration and field notes

Unlike airborne exposure agents, dissolved oxygen is not governed by occupational exposure limits. There is no OSHA PEL, NIOSH REL or ACGIH TLV for it, because it is not an inhalation hazard. It is instead regulated as an ambient water quality criterion: states set numeric dissolved oxygen minimums under the Clean Water Act to support designated aquatic life uses, with coldwater and spawning waters generally carrying higher minimums than warmwater. Discharge permits issued under NPDES commonly carry dissolved oxygen conditions, and wastewater treatment plants track it continuously to control aeration. Waters below roughly 2 mg/L are commonly described as hypoxic. Numeric criteria vary by state and by use classification, so confirm the limits that govern your waterbody before comparing field data against them.

Field measurement is most often made with an optical luminescent sensor, which needs no membrane or electrolyte and holds calibration well. Report both mg/L and percent saturation where you can, and record temperature, salinity and barometric pressure alongside the reading, since all three affect the result.

pH

pH units (0 to 14)

pH is a measure of hydrogen ion activity, and it governs a surprising amount of what else happens in a water body. It controls the solubility and toxicity of metals, determines how much of the total ammonia present exists as the far more toxic un-ionized form, drives the effectiveness of disinfection and coagulation in treatment, and sets how corrosive water will be toward pipes and fittings. Because the scale is logarithmic, a shift of one unit is a tenfold change in hydrogen ion activity, so small numeric movements are not small chemical movements.

Regulation, calibration and field notes

pH is not an inhalation hazard and carries no OSHA PEL, NIOSH REL or ACGIH TLV. It is regulated as a water quality criterion instead. Under the Clean Water Act, states set an acceptable pH range for each designated use rather than a single ceiling value, and NPDES discharge permits routinely carry a pH range condition. Under the Safe Drinking Water Act, pH appears among the National Secondary Drinking Water Regulations, which are non-enforceable guidelines covering taste, odor and appearance rather than health-based limits. Confirm the range that governs your waterbody or discharge before comparing field data against it.

Calibrate with buffers that bracket the values you expect to see. A two-point calibration using 7 plus either 4 or 10 covers most work; use all three when in-situ values are unknown or span both sides of neutral. Record temperature with every reading, check the slope in the calibration record, and expect a typical sensor working life of roughly 12 to 24 months depending on use and storage.

ORP (Oxidation-Reduction Potential)

ORP (mV)

Oxidation-reduction potential expresses the net tendency of a water sample to gain or lose electrons, reported in millivolts. Positive values indicate oxidizing conditions, negative values indicate reducing conditions. It is not a measure of any single substance; it is a summary of the redox state produced by everything present.

Regulation, calibration and field notes

That makes it a diagnostic and process control parameter rather than a compliance number. It is used to control chlorination and other disinfection, since disinfection effectiveness tracks redox potential more directly than residual concentration alone. In wastewater treatment it is used to distinguish aerobic, anoxic and anaerobic zones and to time nitrification and denitrification. In groundwater remediation it helps map redox zones and predict whether contaminants will degrade. It also indicates conditions under which metals become mobile and sulfide forms.

ORP is not an inhalation hazard and has no OSHA PEL, NIOSH REL or ACGIH TLV. It is rarely written into permits as a numeric limit. Its value lies in interpretation alongside dissolved oxygen, pH and temperature rather than in isolation.

Calibrate against a traceable redox standard such as Zobell solution, at a single point. On a combination pH/ORP sensor, calibrate pH first to confirm the sensor is responding before calibrating ORP. Slow stabilization in standard is the usual first sign that the sensor needs cleaning or is nearing end of life.

Conductivity & Salinity

µS/cm, mS/cm, ppt, PSU

Conductivity measures how readily water carries an electrical current, which scales with the concentration of dissolved ions. Specific conductance is the same measurement normalized to 25 °C so that readings taken at different temperatures can be compared. Salinity, total dissolved solids and resistivity are all derived from conductivity and temperature rather than measured independently.

Regulation, calibration and field notes

It is one of the most useful screening parameters in the field because it responds quickly to almost any change in dissolved ion load. Common uses include establishing baseline conditions, detecting saltwater intrusion in coastal aquifers, tracking road salt runoff, identifying produced water or industrial discharge, assessing irrigation suitability, and managing aquaculture systems. A sudden change in conductivity along a reach is often the first indication that something has entered the water.

There are no occupational exposure limits for conductivity or salinity. Total dissolved solids appears among the National Secondary Drinking Water Regulations, which are non-enforceable guidelines addressing taste, odor and appearance rather than health effects. Some states set chloride or specific conductance criteria to protect aquatic life. Confirm what applies to your waterbody and use classification.

A conductivity sensor also underpins other measurements: the salinity value it produces is what an instrument uses to compensate dissolved oxygen in mg/L and to run ammonium, nitrate and chloride algorithms. Calibrate specific conductance with a traceable solution of at least 1.0 mS/cm, matched roughly to your expected range, and check the cell constant in the calibration record afterward.

Water Temperature

°C, °F

Water temperature is the most basic field parameter and the one nearly every other reading depends on. It controls how much oxygen water can hold, how fast chemical and biological processes run, and how conductivity, pH and dissolved oxygen sensors respond, so it is recorded alongside every other measurement.

Regulation, calibration and field notes

Common uses include documenting thermal discharges from power plants and industrial cooling water, checking stream conditions for cold-water fish habitat, profiling stratification in lakes and reservoirs, confirming that groundwater readings have stabilized during low-flow purging before a sample is collected, and managing aquaculture systems.

There are no occupational exposure limits for water temperature. Under the Clean Water Act, states set temperature criteria in their water quality standards to protect aquatic life, and thermal discharges are controlled through NPDES permits. Confirm what applies to your waterbody and use classification.

Field instruments measure water temperature with a thermistor. On many of them, including the YSI ProDSS, the temperature sensor is factory calibrated and is checked against a traceable reference thermometer rather than recalibrated by the user. Because conductivity changes with temperature, instruments report specific conductance normalized to 25 °C, and dissolved oxygen in mg/L depends on accurate temperature compensation.

Turbidity

Turbidity (FNU, NTU)

Turbidity is the reduction in light transmission caused by suspended and colloidal particles: sediment, algae, organic matter and precipitates. It is not a direct measure of any specific substance, but it responds fast and correlates well with suspended solids, which makes it one of the most practical field indicators available. Elevated turbidity smothers habitat, carries adsorbed nutrients and metals with it, and shields pathogens from disinfection.

Regulation, calibration and field notes

Turbidity carries no occupational exposure limit. Under the Safe Drinking Water Act it is central to surface water treatment requirements, where it functions as a treatment performance benchmark and a proxy for filtration effectiveness and pathogen removal rather than as a simple contaminant limit. Under the Clean Water Act it appears in construction stormwater permits, dredging and in-water work conditions, and state surface water criteria, which are frequently written as an allowable increase above background rather than an absolute ceiling. Confirm the form the limit takes for your project, since a background-relative criterion requires an upstream or reference measurement to be defensible.

Calibration is where turbidity data most often goes wrong. Use only standards prepared according to Standard Methods for the Examination of Water and Wastewater, Section 2130 B, and do not mix standard types across points in a multi-point calibration. Keep a calibration cup and sensor guard reserved for calibration alone, since a contaminated zero standard is the usual cause of negative readings in the field.

When do rental charges start? On the Rental Start Date you choose, not the day we ship. See how renting works

Water quality monitoring questions

All rental FAQs →
What do water hazards cover?
The field parameters used to describe the condition of water rather than air: dissolved oxygen, pH, ORP, conductivity and salinity, and turbidity. Together they indicate whether a water body can support aquatic life, whether treatment is working, and whether a discharge is inside permit.
Are water parameters regulated the same way as airborne contaminants?
No. Airborne agents carry OSHA PELs, NIOSH RELs and ACGIH TLVs because they are inhalation hazards. Water parameters are governed instead by the Clean Water Act, NPDES discharge permits, and the Safe Drinking Water Act, where criteria commonly vary by state and by the designated use of the water body.
Can one instrument measure all of these at once?
Yes. A multiparameter meter with a multi-port cable accepts several smart sensors at the same time, so dissolved oxygen, pH, ORP, conductivity and turbidity can all be logged from a single deployment of the probe. Which parameters you get depends entirely on which sensors are fitted.
Which parameters should I measure for my project?
Start from what you have to report. Aquatic life and stream health work centres on dissolved oxygen and temperature. Discharge compliance usually adds pH and turbidity. Remediation and disinfection work adds ORP. Saltwater intrusion, road salt, and produced water investigations centre on conductivity and salinity.
Why do dissolved oxygen readings depend on temperature and salinity?
Oxygen solubility falls as water gets warmer and as it gets saltier, so the same percent saturation corresponds to a different mg/L value depending on conditions. That is why a conductivity and temperature sensor should be installed whenever you are reporting dissolved oxygen in mg/L.
What is the difference between screening data and compliance data?
Screening data tells you where to look and whether something changed. Compliance data has to survive scrutiny, which means a documented calibration before sampling, a recorded method, and traceable standards. The instrument is often the same — the difference is the discipline around it.
How often should I calibrate a dissolved oxygen meter?
YSI recommends calibrating or verifying daily, before sampling starts. Optical DO calibration is very stable, but it should still be checked regularly. The more critical the data — compliance work in particular — the more attention timely calibration deserves. Your data is only as good as your calibration.
What is true barometric pressure, and why does it matter for DO?
True barometric pressure is an uncorrected reading. Laboratory barometers usually give true values and can be used as-is. Weather service readings are corrected to sea level and cannot be used until they are uncorrected. YSI's approximate formula is: True BP = Corrected BP minus [2.5 x (local altitude in feet above sea level / 100)]. Get this wrong and every DO calibration is wrong with it.
Do I need to recalibrate if I move to a different altitude?
No. Dissolved oxygen sensors are calibrated to and measure the partial pressure of oxygen, so after an accurate calibration the sensor compensates for pressure changes automatically. If you are using a DO% Local function, the calibration value stays at 100% regardless of altitude and the internal barometer keeps the saturated value there.
Optical or electrochemical DO sensor — which should I rent?
Optical for almost all field work. There is no membrane to change, no electrolyte, no stirring requirement, and readings stabilize almost immediately after power-on. A polarographic electrochemical sensor needs roughly 5 to 15 minutes to stabilize and its membrane needs changing every 2 to 8 weeks depending on the sampling.
How do I verify a calibration without recalibrating?
Put the sensor back in its calibration environment and compare the reading against the value for the current barometric pressure. If true BP is 750 mmHg, the expected reading is 750/760 x 100 = 98%. Once stable, an optical sensor should sit within about 1% of that figure, and an electrochemical sensor within about 2%.
My percent saturation looks right but mg/L looks wrong. Why?
Almost always a salinity problem. Oxygen solubility drops as salinity rises, and the instrument uses a salinity value to convert saturation into mg/L. If a conductivity sensor is installed and calibrated, that value comes from the sensor. If not, you have to enter it manually — roughly 0 to 0.5 ppt for fresh water, about 35 ppt for seawater.
How many calibration points does pH need?
Two covers most work — buffer 7 plus either 4 or 10, chosen to bracket the values you expect in the field. Use all three when the in-situ pH is unknown or when you expect readings on both sides of neutral. Buffer 7 should be included regardless of how many points you run, though it does not have to be first.
Do I have to enter the buffer values manually?
Not if you are using a standard USA (4, 7, 10) or NIST (4.01, 6.86, 9.18) buffer set — the instrument recognizes those automatically and compensates the calibration value for temperature. Just make sure the correct buffer set is selected in the sensor setup menu, because the wrong one selected is a common cause of a questionable calibration warning.
What millivolt readings indicate a healthy pH sensor?
Buffer 7 should read 0 mV plus or minus 50 mV. Buffer 4 should sit +165 to +180 mV from the buffer 7 value, and buffer 10 should sit -165 to -180 mV from it. If the span between points drops below about 160 mV, clean the sensor and recalibrate before trusting the data.
My pH sensor is responding slowly. What should I do?
If it takes more than about 90 seconds to stabilize in buffer, clean and recondition it. Start gently: a moistened lens tissue or cotton swab on the glass bulb, then carefully clear the reference junction. Escalate to a mild detergent soak only if that does not restore response.
How should a pH sensor be stored between jobs?
Moist, never dry. pH 4 buffer makes a good storage solution. If a sensor has been allowed to dry out, or has been sitting in distilled or deionized water for a long period, soaking it in buffer 4 overnight will often bring it back. Typical working life is roughly 12 to 24 months depending on how it is used and stored.
Does pH affect my other measurements?
Yes, in two directions. pH governs how much of the total ammonia present exists in the far more toxic un-ionized form, and it controls metal solubility — so it changes how other results should be interpreted. It also works the other way: the high ionic content of pH buffers causes real but temporary drift in ammonium, nitrate and chloride sensors, so plan the calibration order around that.
What does ORP actually tell me?
Whether the water is oxidizing or reducing overall, in millivolts. Positive values mean oxidizing conditions, negative mean reducing. It is not a measure of any single substance — it summarizes the redox state produced by everything present, which makes it a diagnostic parameter rather than a compliance number.
Do I calibrate ORP the same way as pH?
No — ORP is a single point, typically against Zobell solution, and many instruments adjust the calibration value for temperature automatically. If you are using a combination pH/ORP sensor, calibrate pH first to confirm the sensor is responding properly before calibrating ORP.
Why is ORP used to control disinfection?
Disinfection effectiveness tracks redox potential more directly than residual concentration alone does. A residual figure tells you how much disinfectant is present; ORP tells you what the water is actually doing chemically. Most operators use both together rather than either on its own.
Should I rent a pH-only sensor or a combination pH/ORP sensor?
Take the combination sensor if there is any chance you will want ORP, since it delivers both parameters from a single port and leaves the remaining ports free for other measurements. Take pH-only when ports are tight and ORP is definitely not part of the scope.
How do I know when an ORP sensor is worn out?
Perform a factory reset on the sensor, then compare its millivolt reading in Zobell solution against the solution's calibration value. The difference should be under 100 mV. At 80 mV or more, the sensor is nearing the end of its life and should be replaced rather than nursed along.
My ORP readings drift or take a long time to settle. What now?
If it takes more than about 90 seconds to stabilize in Zobell, clean and recondition the sensor. Check the calibration solution has not expired, since ORP standards degrade. Typical working life for an ORP sensor is roughly 12 to 24 months depending on use, storage and maintenance.
Which conductivity calibration solution should I use?
Match it roughly to the water you are measuring: 1.0 mS/cm for fresh water, 10 mS/cm for brackish and estuarine, 50 mS/cm for salt water. Never calibrate with a solution below 1.0 mS/cm — you are setting the slope on a linear device, and a weak signal gives poor performance. Note that 1.0 mS/cm equals 1000 uS/cm; mixing those up is a common calibration error.
Do I calibrate conductivity, specific conductance and salinity separately?
No. Calibrating any one of them calibrates the others at the same time. Calibrate specific conductance — temperature-compensated conductivity — for the best combination of ease and accuracy.
Why is my conductivity reading about half what I expect?
The solution is almost certainly not covering the vent holes on the sensor. If the entire sensor is not immersed, the instrument reads roughly half the expected value. Fill the calibration cup properly, then move the sensor gently up and down to dislodge any air bubbles trapped inside the cell.
What cell constant should I see after calibration?
Check the GLP record after accepting a calibration. Around 5.0 to 6.0 indicates the highest accuracy, and the broader acceptable range runs 4.5 to 6.5. A significant jump in cell constant between one calibration and the next usually means either the standard or the sensor has a problem — most often a sensor that needs cleaning.
How do I know when a conductivity sensor needs cleaning?
A clean, dry conductivity sensor reads less than 1 uS/cm in air. If it is dry and reading higher than that, clean it. Use the small brush supplied with the sensor, dipped in clean water and inserted into each opening 10 to 12 times, with a mild detergent if deposits have formed.
Why does a conductivity sensor matter for my other readings?
Because accurate temperature compensation is required for nearly every other parameter, and the salinity value from this sensor feeds the dissolved oxygen mg/L calculation along with the ammonium, nitrate and chloride algorithms. Accepting a questionable conductivity calibration will quietly corrupt your DO data too.
Which turbidity standards are approved?
Only standards prepared according to Standard Methods for the Examination of Water and Wastewater, Section 2130 B. That covers AMCO-AEPA standards made specifically for the sensor, formazin prepared per Standard Methods, dilutions of 4000 FNU formazin concentrate, and StablCal standards. Standards from other sources will likely produce a bad calibration and wrong field readings.
Why am I getting negative turbidity readings?
The zero standard was contaminated. Even a brand new instrument can contaminate a zero standard to around 0.1 FNU in a lab, and cleaned but used sensors, cups and guards can push it close to 1.0 FNU. If your actual reading in the zero standard is 0.6 FNU but you entered 0, a sample at 0.3 FNU will display as -0.3 FNU.
How do I stop negative readings happening?
Keep a calibration cup and sensor guard used only for calibration and never taken into dirty water. Where equipment is properly cleaned, typical contamination runs 0.2 to 0.8 NTU, so entering a first calibration point between 0 and 1 FNU is acceptable practice. Calibrate in a lab rather than in the field where you can.
Do I need the sensor guard installed?
Yes, for both calibration and every measurement. The guard has a black-painted metal bottom that eliminates stray light reflection, which the optical measurement depends on. Check that inner surface is not badly scratched, and keep both guard and cup free of anything reflective.
How do I avoid air bubbles during turbidity calibration?
Pour the standard slowly down the side of the container rather than straight in, so you do not aerate it. Then lower the sensor in slowly with the cup tilted at roughly 45 degrees. Bubbles clinging to the sensor face read as particles and will skew the calibration.
FNU or NTU — does the unit matter?
Both describe the same 90 degree scatter measurement, but they come from different reference methods using different light sources, so values are not always interchangeable — particularly in coloured water. Check which unit your permit or method requires and report in that unit rather than converting.

Not sure which sensors your job needs?

Tell us what you're sampling and which parameters your permit or project calls for. We'll recommend the sensor setup.

For educational purposes only. Water quality criteria and permit limits vary by state, waterbody and use classification; confirm the requirements for your site with your permitting authority or a qualified professional.