AIR XS by Trolex - Area Silica Monitor

Area Monitoring Datalogging
Particle Counter Manufacturer: Trolex
AIR XS by Trolex - Area Silica Monitor
AIR XS by Trolex - Area Silica Monitor
AIR XS by Trolex - Area Silica Monitor
AIR XS by Trolex - Area Silica Monitor
AIR XS by Trolex - Area Silica Monitor

The Trolex AIR XS is a real-time area monitor for respirable crystalline silica (RCS) using Optical Refraction Technology (ORT) to continuously detect hazardous silica and total dust concentrations. It measures RCS particles from 1–10 Β΅m across a range of 0–1,000 Β΅g/mΒ³ with resolution to 0.001 mg/mΒ³. Sampling intervals are configurable from 1 to 60 seconds, with rolling averages from 15 minutes to 12 hours. Battery life is 8–10 hours with continuous AC power operation also available. Compliant with NIOSH 7500/7602 and OSHA silica standards. Suited for mining, construction, and industrial hygiene programs requiring continuous, real-time silica exposure data without laboratory turnaround delays.

Choose Your Option

Rent for flexible short-term use or purchase to own

Rent
Purchase
Rental Rates
Daily
$300.00
Weekly
$850.00
Monthly
Contact for pricing
Reference rates only. You get the best rate calculation - actual price based on your selected rental dates.
Need Help Choosing?
Our rental specialists can help you select the right equipment for your specific application.
Call 866-736-8347
1
Choose Purchase Option
Rent short-term or buy to own
Required

No rental period selected

Set your dates to see pricing.

β€”
Important: These dates apply to your entire cart. Changing dates will affect pricing for all rental items in your cart.

Need equipment sooner than the dates shown? We can often accommodate rush rentals. Call us at 866-736-8347 to confirm availability.

Used Equipment: This equipment has been previously used and tested. It may show signs of wear but is fully functional and inspected.

Your Configuration

AIR XS by Trolex - Area Silica Monitor
unit quantity
Γ— $300.00
$300.00 Select dates
Subtotal:
$300.00
Select dates
Technician verified and tested instrumentation before every rental
Expert support available by phone and email
Fast delivery and flexible rental terms
What is the Trolex AIR XS used for?
It's a real-time area monitor for respirable crystalline silica (RCS) in construction, mining, and industrial environments. Unlike photometer-only dust monitors, it combines a photometer with an inline XRF module to report actual RCS concentration β€” not just total dust β€” without waiting on lab results.
How does the AIR XS detect respirable crystalline silica in real time?
It uses patented Optical Refraction Technology (ORT) combined with light-scatter photometry. A laser is shone through each particle and its refraction is captured on multiple sensors, classifying particles by size, symmetry, and optical markers unique to crystalline silica. This gives real-time RCS concentration data β€” distinguishing silica from other dust β€” rather than a total dust proxy.
AIR XS vs. a photometer-only dust monitor β€” why does ORT matter?
A photometer alone measures total or respirable dust mass but cannot distinguish silica from other particles. In mixed-dust environments, photometer-only results may significantly over- or under-estimate actual RCS exposure. The AIR XS adds Optical Refraction Technology (ORT) to identify the crystalline silica fraction directly, capturing all forms of RCS including quartz, cristobalite, and tridymite.
Is real-time silica monitoring compliant with OSHA's silica standard (29 CFR 1926.1153 / 1910.1053)?
OSHA's silica standard currently references gravimetric sampling as the compliance method for exposure determination. Use the AIR XS for real-time process control, early warning, and directing controls β€” use gravimetric sampling for formal compliance documentation.
What site conditions affect AIR XS accuracy?
Humidity extremes, very high dust loading that may saturate the sensor, and variable dust composition can affect readings. At very low dust concentrations there are fewer particles for the ORT sensor to classify, increasing uncertainty in the silica fraction estimate. Typical RCS accuracy is around Β±25%.
What does it cost to rent the Trolex AIR XS?
Contact RAECO Rents for current daily and weekly rates. Real-time silica monitoring projects typically run continuously during active work β€” contact us with your monitoring duration and site type for a project quote.

Exposure Hazards This Equipment Detects

Crystalline Silica Dust (RCS)

CAS: 14808-60-7
Learn More
Updated on March 09, 2026
PEL TWA
50 Β΅g/mΒ³ [25 Β΅g/mΒ³ Action Level] [29 CFR 1910.1053]
REL TWA
0.05 mg/mΒ³ (Ca β€” carcinogen, reduce to lowest feasible concentration)
TLV TWA
0.025 mg/mΒ³ (respirable particulate matter) [2009]

Features & Capabilities

Datalogging: βœ“ Yes
Monitoring Scope: Area Monitoring

Equipment Specifications

Sensing Technology: Sensing technology Optical refraction technology (ORT) ,Β Light-scatter photometer (OPC)

Particulate Measurement: Target RCS identification range 1 to 10 Β΅m

Max. typical dust loading*:150 mg/mΒ³- *The instrument can define particulate measurement peak trends up to the quantity specified.

Continuous range:25 mg/mΒ³

Displayed data: RCS mg/mΒ³ & Total particles/litre

Resolution:1Β΅g (1,000th of a mg)

Averaging period:15 minutes, 1, 4, 8 and 12 hours (rolling average)

Sampling interval:1 to 60 seconds

Particle count:> 600 particles/second

Total airflow rate: ~1.5 L/m (nominal)

Typical RCS accuracy: Β± 25%

Kit Contents

Air XS, External Battery Pack x2, Battery Pack Case, Battery Charger, (4) Spare 5A Blade Fuses for Battery Case, AC Power Cable, Tripod, Compliance Hood, Spray Bottle & Silica Container, Panel Key, Spare Internal filters x2, Screws & Nuts 4x of Each: M8 (Pre-Installed on AIR XS Backplate Mount), Tripod Mount Piece B & E, with Screws & Nuts, Toolbox with Tool Kit: Small Flathead Screwdriver (For Opening AC/DC Power Ports), Large Flathead Screwdriver, Phillips Screwdriver, 3/8" Nut Driver, 7/16" Nut Driver, Slip-Nut Pliers, Needlenose Pliers, 5/16" Hex Wrench, Small Flathead to Open AC/DC Power Ports, USB Cable A to B, User Manuals / Quick Start Guides – May be on Flash Drive Only, Breathe XS Software (on flash drive), Calibration Certificates (emailed)

Manufacturer Resources

Documents

User manuals, safety guides, and technical documentation from the manufacturer:

Videos

Product demonstrations and instructional videos from the manufacturer:

Ask a Question

Have a question about this product? Fill out the form below and our team will get back to you shortly.

Need Help Choosing the Right Equipment?

Our customer success specialists are here to help you select the perfect equipment for your project