AeroQual Series 500 - Portable Ozone Monitor
AeroQual Series 500 - Portable Ozone Monitor
The AeroQual Series 500 is a portable ozone monitoring platform compatible with interchangeable sensor modules for ozone and other gas measurements. This gently used unit is available for sale and comes with a charger, hard plastic carrying case, PC communication cables, and a flash drive with software and manuals. Sensors are not included with this sale. For rental applications, the AeroQual Series 500 has been replaced by the Aeroqual Ranger Portable Ozone Monitor.
Choose Your Option
Rent for flexible short-term use or purchase to own
Exposure Hazards This Equipment Detects
Ozone (O₃)
Features & Capabilities
| Datalogging: | ✓ Yes |
Equipment Specifications
| Detection Method / Sensor Type: | Interchangeable sensor head — OZL gas-sensitive semiconductor (GSS) for low range, or EOZ gas-sensitive electrochemical (GSE) for high range |
| Target Gas/Analyte: | Ozone (O3) |
| Measurement Range: | OZL (GSS, low range): 0 to 0.5 ppm. EOZ (GSE, high range): 0 to 10 ppm |
| Relative Humidity Range: | Monitor: 0% to 95% non-condensing. OZL sensor head: 10% to 90% RH. EOZ sensor head: 15% to 90% RH |
| Response Time: | 60 seconds |
| Resolution: | OZL: 0.001 ppm. EOZ: 0.01 ppm |
| Accuracy: | OZL: <±0.008 ppm from 0-0.1 ppm, <±10% from 0.1-0.5 ppm. EOZ: <±0.01 ppm + 7.5% of reading. Minimum detection limit OZL 0.001 ppm, EOZ 0.01 ppm |
| Sampling Modes: | Real-time reading with minimum, maximum and average measurement cycle |
| Alarm Features: | Audible low and high alarm with user-set alarm points; temporary or permanent mute |
| Additional Features: | Sensor warm-up: 3 minutes warming up then 7 minutes stabilising. New or long-unused ozone sensors may require up to 24 hours to burn off contaminants |
| Calibration Method: | Factory calibration with certificate, or field zero and span calibration via the Series 500 base. Ozone span calibration requires an ozone generator — ozone cannot be supplied from a cylinder |
| Connectivity: | RS232 with USB converter; 0-5V analogue output; external transistor outputs for alarm and control (12 VDC or switch to GND, 150 mA max) |
| Display: | LCD with status indicators for battery, sensor, standby, mute, high/low alarm, monitor ID and location ID |
| Operating Temperature Range: | Monitor: 23°F to 113°F (-5°C to 45°C). Sensor heads: 32°F to 104°F (0°C to 40°C) |
| Protection Class: | IP20 and NEMA 1 equivalent; PC and ABS enclosure |
| Data Logging Interval: | User-selectable in 1-minute increments |
| Data Storage Capacity: | 8,188 data points total, divided by the number of parameters logged |
| Battery Run Time: | Approximately 8 hours depending on sensor head; 3 hours to full charge. Ni-MH 9.6V 2100mA/h or Lithium 11.1V |
| Power Supply: | 12V DC via supplied 100-250V AC adaptor/charger |
| Size / Weight: | 195 x 122 x 54 mm with sensor head; under 460 g with sensor head and battery |
| Regulatory Certifications: | FCC Part 15, EN 50082-1:1997, EN 50081-1:1992 |
Manufacturer Resources
Documents
Manufacturer documentation is available upon request. Please contact our team for manuals, safety guides, and technical specifications.
Videos
No manufacturer videos are currently available for this product. Check back later or contact us for more information.
Ask a Question
Have a question about this product? Fill out the form below and our team will get back to you shortly.
- Translation missing: en.general.accessibility.refresh_page
- Translation missing: en.general.accessibility.new_window