EBT731 Balometer by TSI Alnor - Capture Hood
Available
EBT731 Balometer by TSI Alnor - Capture Hood
The EBT731 Balometer by TSI Alnor is a capture hood flow meter designed for fast, accurate measurement of supply and return airflow at diffusers and grilles in HVAC commissioning and balancing applications. It measures airflow from 25–2,500 CFM with an accuracy of ±3% ±7 ft/min, and its onboard memory stores over 26,500 samples for thorough documentation of balanced systems. Weighing 7.4 lbs with approximately 12 hours of battery life, it is well-suited for HVAC system commissioning, energy audits, cleanroom qualification, and indoor air quality investigations.
Choose Your Option
Rent for flexible short-term use or purchase to own
Exposure Hazards This Equipment Detects
Air Velocity (CFM / ft/min)
Features & Capabilities
| Calibration Certificate Available: | ✓ Yes |
| Datalogging: | ✓ Yes |
| Monitoring Scope: | Area Monitoring |
Equipment Specifications
| Type/Class Rating: | Capture Hood — Standard-Flow Balometer |
| Measured Parameters: | Airflow (Volumetric), Air Velocity (with Pitot Probe, Air Flow Probe, or Velocity Matrix), Differential/Absolute Pressure, Temperature (with optional probe), Relative Humidity (with optional probe) |
| Measurement Range: | Airflow: 25–2,500 ft³/min (42–4,250 m³/h), supply and return; Velocity: 25–15,500 ft/min (0.125–78 m/s) with pitot probe, 25–5,000 ft/min (0.125–25 m/s) with air flow probe, 25–2,500 ft/min (0.125–12.5 m/s) with velocity matrix; Differential Pressure: ±15 in. H2O (3,735 Pa), 150 in. H2O max safe operating pressure; Absolute Pressure: 15–40 in. Hg (356–1,016 mm Hg); Temperature: 14–140°F (–10 to 60°C) with temperature/RH probe; Relative Humidity: 5–95% RH |
| Response Time: | Differential pressure sensor: 2 to 8 seconds |
| Resolution: | Pressure: 0.00001 in. H2O (0.001 Pa) static and differential, 0.01 in. Hg (1 mm Hg) absolute; Velocity: 1 ft/min (0.01 m/s); Airflow: 1 ft³/min (1 m³/h); RH: 0.1% RH; Temperature: 0.1°F (0.1°C) |
| Accuracy: | Pressure: ±2% of reading ±0.0001 in. H2O (0.025 Pa) static and differential, ±2% of reading absolute; Velocity: ±3% of reading ±7 ft/min (0.04 m/s) above 50 ft/min; Airflow: ±3% of reading ±7 ft³/min (12 m³/h) above 50 ft³/min; RH: ±3% RH; Temperature: ±0.5°F (0.3°C) |
| Connectivity: | USB data transfer via TrakPro software |
| Compatible Probes / Accessories: | 18-inch Pitot probe, Static pressure probes, Temperature probe, Humidity probe, 16-Point Velocity Matrix, 2×2 ft fabric hood |
| Data Logging Interval: | User selectable |
| Data Logging Capacity: | 26,500 samples, time and date stamped |
| Battery Run Time: | Four AA rechargeable NiMH (included) or alkaline, or AC adapter (included); minimum of 12 hours typical; 4-hour recharge via internal charger |
| Size / Weight: | Manometer: 7.4 × 4.5 × 2.3 in. (18.8 × 11.4 × 5.8 cm); 7.4 lb (3.4 kg) with batteries |
Kit Contents
Manufacturer Resources
Documents
User manuals, safety guides, and technical documentation from the manufacturer:
Videos
Product demonstrations and instructional videos from the manufacturer:
Ask a Question
Have a question about this product? Fill out the form below and our team will get back to you shortly.
- Translation missing: en.general.accessibility.refresh_page
- Translation missing: en.general.accessibility.new_window