SciAps X-550 XRF Analyzer - Lead Paint
Available
SciAps X-550 XRF Analyzer - Lead Paint
The SciAps X-550 (Lead Paint) is a handheld XRF analyzer configured exclusively for HUD-compliant lead-based paint testing. Using a high-resolution silicon drift detector (SDD), it delivers initial results in 1 second with automatic updates for increased precision. Substrate correction and GPS-tagged results support HUD/EPA compliance documentation. An integrated micro and macro camera enables photo-documentation of test areas. Runs on Android OS with built-in Wi-Fi and Bluetooth. Well-suited for pre-renovation screening, LEED testing, and lead paint compliance programs.
Choose Your Option
Rent for flexible short-term use or purchase to own
Exposure Hazards This Equipment Detects
Lead (Pb)
Features & Capabilities
| Datalogging: | ✓ Yes |
| Monitoring Scope: | Area Monitoring |
Equipment Specifications
| Excitation Source: | 5 W X-ray tube: 40 kV, 200 µA rhodium (Rh) anode |
| Detector Type: | 20 mm² silicon drift detector (SDD), 140 eV resolution FWHM at 5.95 keV Mn K-alpha line |
| X-ray Filtering: | Standard 1-position filter (upgradeable to 5 positions with additional apps) |
| Analytical Range: | Pb (lead) standard - this unit is calibrated for Lead Paint testing only; up to 32 elements available with additional app upgrades (not installed on this unit) |
| Result Speed: | Lead paint: Quick mode about 2–6 seconds (stops once the result is above or below the action level at 95% confidence); Timed mode fixed 10 seconds |
| Available Apps: | Lead Paint |
| Exposure Action/Limit Values: | HUD Performance Characteristic Sheets (PCS) at 0.5, 0.7 and 1.0 mg/cm² action levels; no substrate correction. Rhodium anode: no inconclusive range at 0.5 or 1.0 mg/cm²; at 0.7 mg/cm², none in Quick mode and 0.6–0.7 mg/cm² in Timed mode |
| Calibration Method: | Calibrated/verified using the included metal calibration clip (stainless steel check standard) and wooden lead paint calibration standard block; no additional application-specific calibration standards included, regardless of installed apps |
| Calibration Standard: | External 316 stainless steel check standard for energy calibration; NIST 1.04 mg/cm² lead paint standard on a wooden block for the HUD PCS calibration check |
| Connectivity: | Wi-Fi, Bluetooth, GPS, USB, SciAps Profile Builder PC software |
| Camera: | Integrated micro and macro camera for photo-documentation |
| Display: | 2.7-inch color capacitive touchscreen |
| Operating Temperature Range: | 10°F to 130°F at 25% duty cycle |
| Battery Run Time: | 6 to 8 hours on one battery; hot-swap battery (60 s maximum swap time); rechargeable in the analyzer or an external charger, or AC power |
| Size / Weight: | 8.5 x 9.5 x 2.4 in; 2.98 lb with battery |
| Regulatory Certifications: | CE, RoHS, USFDA registered, Canada RED Act |
Kit Contents
Manufacturer Resources
Documents
User manuals, safety guides, and technical documentation from the manufacturer:
Videos
Product demonstrations and instructional videos from the manufacturer:
Ask a Question
Have a question about this product? Fill out the form below and our team will get back to you shortly.
- Translation missing: en.general.accessibility.refresh_page
- Translation missing: en.general.accessibility.new_window