SciAps X-550 XRF Analyzer - Lead Paint & RCRA/Soils
Available
SciAps X-550 XRF Analyzer - Lead Paint & RCRA/Soils
The SciAps X-550 (Lead Paint & RCRA/Soils) is a handheld XRF analyzer configured for HUD-compliant lead-based paint testing and environmental RCRA screening. The Soil App uses Compton normalization to target 24 elements, including all 8 RCRA metals (As, Ba, Cd, Cr, Pb, Hg, Se, Ag) and 12 of the 13 EPA Priority Pollutant Metals. The Lead Paint App delivers HUD-compliant screening with substrate correction and GPS-tagged results. Initial analysis in 1 second with automatic updates. Includes an integrated micro and macro camera for photo-documentation and built-in Wi-Fi and Bluetooth. Well-suited for Phase II ESAs, brownfield investigations, RCRA site characterization, and lead paint compliance programs.
Choose Your Option
Rent for flexible short-term use or purchase to own
Exposure Hazards This Equipment Detects
Lead (Pb)
Features & Capabilities
| Datalogging: | ✓ Yes |
| Monitoring Scope: | Area Monitoring |
Equipment Specifications
| Excitation Source: | 5 W X-ray tube: 40 kV, 200 µA rhodium (Rh) anode |
| Detector Type: | 20 mm² silicon drift detector (SDD), 140 eV resolution FWHM at 5.95 keV Mn K-alpha line |
| X-ray Filtering: | 6-position filter wheel for beam optimization |
| Analytical Range: | Lead Paint (Pb) plus Soil App (Compton Normalization) covering Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Sr, S, Rb, Zr, Mo, Hg, Tl, Pb, Ag, Cd, Sn, Sb, Ba - includes all 8 RCRA metals and 12 of the 13 EPA Priority Pollutant Metals |
| Result Speed: | Lead paint: Quick mode about 2–6 seconds (stops once the result is above or below the action level at 95% confidence); Timed mode fixed 10 seconds; soil detection limits are quoted at 120-second tests |
| Available Apps: | Lead Paint, RCRA/Soils |
| Exposure Action/Limit Values: | HUD Performance Characteristic Sheets (PCS) at 0.5, 0.7 and 1.0 mg/cm² action levels; no substrate correction. Rhodium anode: no inconclusive range at 0.5 or 1.0 mg/cm²; at 0.7 mg/cm², none in Quick mode and 0.6–0.7 mg/cm² in Timed mode |
| Calibration Method: | Calibrated/verified using the included metal calibration clip (stainless steel check standard) and wooden lead paint calibration standard block; no additional application-specific calibration standards included, regardless of installed apps |
| Calibration Standard: | External 316 stainless steel check standard for energy calibration; NIST 1.04 mg/cm² lead paint standard on a wooden block for the HUD PCS calibration check |
| Connectivity: | Wi-Fi, Bluetooth, GPS, USB, SciAps Profile Builder PC software |
| Camera: | Integrated micro and macro camera for photo-documentation |
| Display: | 2.7-inch color capacitive touchscreen |
| Operating Temperature Range: | 10°F to 130°F at 25% duty cycle |
| Battery Run Time: | 6 to 8 hours on one battery; hot-swap battery (60 s maximum swap time); rechargeable in the analyzer or an external charger, or AC power |
| Size / Weight: | 8.5 x 9.5 x 2.4 in; 2.98 lb with battery |
| Regulatory Certifications: | CE, RoHS, USFDA registered, Canada RED Act |
Kit Contents
Manufacturer Resources
Documents
User manuals, safety guides, and technical documentation from the manufacturer:
Videos
Product demonstrations and instructional videos from the manufacturer:
Ask a Question
Have a question about this product? Fill out the form below and our team will get back to you shortly.
- Translation missing: en.general.accessibility.refresh_page
- Translation missing: en.general.accessibility.new_window