The Aeroqual AQS 1 is a compact, near-reference, real-time air quality monitor for outdoor particulate and gas monitoring projects. Housed in a rugged, weatherproof enclosure with a modular design, it can measure multiple PM size fractions and up to three gas pollutants simultaneously while sending remote, real-time data to Aeroqual monitoring software.

Use the AQS 1 for construction and remediation air monitoring, fenceline and fugitive dust monitoring, industrial site monitoring, landfill monitoring, quarry and mining operations, urban air quality networks, and community air quality studies where defensible real-time data is needed.

What it measures:
- Particulate matter: PM1, PM2.5, PM4, PM10, and TSP
- Gas pollutants: VOCs, O3, NO2, CO, H2S, SO2, and CH4
- Environmental factors: temperature, humidity, noise, barometric pressure, precipitation, solar radiation, wind speed, and wind direction depending on configuration

Key technology:
- Pumped sampling system provides reliable flow to sensor modules and uses built-in filters to help protect gas sensors from airborne dust.
- Automatic Baseline Correction auto-corrects the zero baseline for gas measurement to reduce drift and cross-interference.
- The NO2 module uses an integrated O3 filter to reduce ozone interference.
- The PCX module measures multiple PM size fractions with automatic flow control and an efficient inlet heater to reduce humidity interference.
- PCX Smart Heater and Aeroqual Cloud Power Scheduler features can reduce energy use for off-grid or cold-weather deployments.
- The AQS 1 is factory calibrated using NIST-traceable reference materials.

Common applications include Construction Environmental Management Plans (CEMP), Remediation Community Air Monitoring Plans (CAMP), fenceline and fugitive dust emissions monitoring, landfill monitoring, industrial and occupational hygiene monitoring, HSE monitoring, and urban/community air monitoring networks.

Calibration and service planning: The AQS 1 is delivered with NIST-traceable factory calibration. Aeroqual states that most users can depend on 12-month factory calibration for gas modules. PM engine service intervals depend on the particle module: the AQS 1 Particle Monitor is recommended at 24 months, while the AQS 1 Particle Profiler is recommended at 12 months. Confirm the exact PM and gas module configuration before quoting.

Availability note: RAECO Rents is evaluating customer interest in this product. Request availability and project requirements so our team can confirm configuration, lead time, and whether the AQS 1 is the right fit for your monitoring objective.

Contact Us for Pricing & Availability
This item requires custom configuration. Our rental specialists will help you select the right options and provide accurate pricing for your specific needs.
Need Help Choosing?
Our rental specialists can help you select the right equipment for your specific application.
Call 866-736-8347
1
Choose Purchase Option
Rent short-term or buy to own
Required

Your Configuration

Aeroqual AQS1 Air Quality Monitor
unit quantity
× $0.00
$0.00 Select dates
Subtotal:
$0.00
Select dates
Technician verified and tested instrumentation before every rental
Expert support available by phone and email
Fast delivery and flexible rental terms
What is the Aeroqual AQS 1 used for?
The Aeroqual AQS 1 is used for continuous outdoor air quality monitoring where a project needs real-time particulate and gas data. Typical uses include construction and remediation air monitoring, fenceline and fugitive dust monitoring, landfill monitoring, quarry and mining dust control, industrial site monitoring, and urban/community air quality studies.
What particulate sizes does the AQS 1 measure?
Depending on configuration, the AQS 1 can measure PM1, PM2.5, PM4, PM10, and TSP in real time.
Can the AQS 1 measure PM10 and PM2.5 simultaneously?
Yes. When configured with the PCX Particle Module, the AQS 1 measures PM1, PM2.5, PM4, PM10, and TSP as standard.
Is the AQS 1 certified for PM monitoring?
The AQS 1 PM10 nephelometer configuration is listed as MCERTS certified and South Coast AQMD Rule 1466 pre-approved. Confirm the exact PM module and configuration before using certification claims in a project submittal.
Does the AQS 1 ship with calibration documentation?
Yes. Aeroqual states the AQS 1 is delivered with NIST-traceable factory calibration. The calibration certificate and interval depend on the exact PM and gas module configuration.
How often does the AQS 1 need calibration?
Gas modules can generally rely on 12-month factory calibration for normal users. PM engine intervals depend on configuration: Aeroqual lists 24 months for the AQS 1 Particle Monitor and 12 months for the AQS 1 Particle Profiler. For the likely multi-size PM1/PM2.5/PM4/PM10/TSP configuration, plan around annual PM engine service unless Aeroqual confirms otherwise.
What gases can the AQS 1 monitor?
The AQS 1 can be configured for up to three gases at the same time, with options including VOCs, ozone (O3), nitrogen dioxide (NO2), carbon monoxide (CO), hydrogen sulfide (H2S), sulfur dioxide (SO2), and methane (CH4).

Exposure Hazards This Equipment Detects

Particulate Matter (PM₂.₅ / PM₁₀)

CAS: N/A
Learn More
Updated on March 09, 2026
PEL TWA
N/A
REL TWA
N/A
TLV TWA
N/A

Ozone (O₃)

CAS: 10028-15-6
Learn More
Updated on October 08, 2026
PEL TWA
0.1 ppm (0.2 mg/m³)
REL TWA
N/A
TLV TWA
Heavy work: 0.05 ppm (0.10 mg/m³); Moderate work: 0.08 ppm (0.16 mg/m³); Light work: 0.10 ppm (0.20 mg/m³) [1995]

Nitrogen Dioxide (NO₂)

CAS: 10102-44-0
Learn More
Updated on October 08, 2026
PEL TWA
N/A
REL TWA
N/A
TLV TWA
0.2 ppm (0.38 mg/m³)

Carbon Monoxide (CO)

CAS: 630-08-0
Learn More
Updated on October 08, 2026
PEL TWA
50 ppm (55 mg/m³)
REL TWA
35 ppm (40 mg/m³)
TLV TWA
25 ppm (29 mg/m³)

Sulfur Dioxide (SO₂)

CAS: 7446-09-5
Learn More
Updated on October 08, 2026
PEL TWA
5 ppm (13 mg/m³)
REL TWA
2 ppm (5 mg/m³)
TLV TWA
N/A

Hydrogen Sulfide (H₂S)

CAS: 7783-06-4
Learn More
Updated on October 08, 2026
PEL TWA
N/A
REL TWA
N/A
TLV TWA
1 ppm [2009]

Methane (CH₄)

CAS: 74-82-8
Learn More
Updated on October 08, 2026
PEL TWA
No established PEL
REL TWA
No established REL
TLV TWA
No TLV; simple asphyxiant (see ACGIH Appendix F: Minimal Oxygen Content)

Volatile Organic Compounds (VOCs)

CAS: N/A
Learn More
Updated on March 09, 2026
PEL TWA
N/A
REL TWA
N/A
TLV TWA
N/A

Features & Capabilities

Calibration Certificate Available: ✓ Yes
Datalogging: ✓ Yes
Monitoring Scope: Area Monitoring

Equipment Specifications

Detection Method / Sensor Type: PCX: 650 nm laser hemispherical-focusing optical particle counter, 1 L/min with active flow control. O3: Gas-sensitive semiconductor (GSS). NO2: Electrochemical with integrated O3 filter and automatic baseline correction. CO: Electrochemical. SO2: Electrochemical with automatic baseline correction. H2S: Electrochemical with automatic baseline correction. VOC: Photoionization detector (PID), calibrated to isobutylene. CH4: Gas-sensitive semiconductor (GSS)
Measured Parameters: Particulate matter (PCX optical particle counter): PM1, PM2.5, PM4, PM10, TSP, Gases (up to three modules): O3, NO2, CO, SO2, H2S, CH4, VOC, Built-in temperature and humidity sensor (PCX), Optional add-on sensors: wind speed and direction, weather, noise, solar radiation
Size Fractions Measured: PM1, PM2.5, PM4 (Respirable), PM10, TSP
Particle Size Range: 0.1 to 40 µm
Measurement Range: Particle range: PCX 0 to 30 mg/m³ (0 to 30000 µg/m³). O3: 0 to 500 ppb. NO2: 0 to 500 ppb. CO: 0 to 25 ppm. VOC (low range): 0 to 500 ppb. VOC (high range): 0 to 30 ppm. H2S: 0 to 5000 ppb. SO2: 0 to 10000 ppb. CH4: 0 to 500 ppm
Resolution: PM: 0.1 µg/m³. O3: 0.1 ppb. NO2: 0.1 ppb. CO: 0.001 ppm. VOC (low range): 0.1 ppb. VOC (high range): 0.01 ppm. H2S: 0.1 ppb. SO2: 0.1 ppb. CH4: 0.01 ppm
Accuracy: PM2.5 (representative): PCX under 5% of reading, precision ±3%, zero stability ±0.1 µg/m³ over 24 hours. Gas precision: O3 and NO2 2% of reading or 2 ppb; CO 3% of reading or 0.05 ppm; VOC 2% of reading or 1 ppb (low range) or 0.05 ppm (high range); H2S 1% of reading or 3 ppb; SO2 0.14% of reading or 2 ppb; CH4 0.4% of reading or 0.06 ppm. Gas linearity (% of full scale): O3, CO and VOC (low range) 1%; NO2 1.5%; VOC (high range) 2%; H2S 0.5%; SO2 0.6%; CH4 under 1%
Sampling Modes: Averaging periods from 1 minute to 24 hours; gas modules update about once per minute
Additional Features: Omni-directional heated PM inlet; inert glass-coated stainless steel and Teflon gas inlet; long-life brushless DC diaphragm pumps; filter-change and pump-wear notifications (PCX); two-way communications for remote calibration, troubleshooting and settings; optional 0-5 V analog input, 4-20 mA input and relay output (PDI Core upgrade); pole, tripod and wall mounting brackets included
Calibration Method: PM auto-zero on start-up and at user-selected intervals. Gas modules can be field calibrated against US EPA protocol gas standards
Calibration Standard: Factory calibrated; gas modules traceable to NIST Standard Reference Materials
Recalibration Interval: PCX particle module: factory calibration every 24 months. Gas modules: as required
Connectivity: WiFi, Ethernet (LAN), Optional 4G LTE cellular modem, Aeroqual Cloud air monitoring software
Optional Sensors: Gill WindSonic ultrasonic wind sensor, Vaisala WXT536 weather transmitter, Cirrus MK427 Class 1 noise sensor, NovaLynx pyranometer (solar radiation), Airmar 200WX weather station
Operating Temperature Range: 14°F to 113°F (-10°C to 45°C); low-temperature operation extendable with a winterization pack
Protection Class: Lockable IP65 GRP cabinet with integrated aluminum solar shield
Data Storage Capacity: On-board storage for more than 5 years of data
Battery Run Time: No internal battery. Runs on AC power (100 to 260 VAC) or an external 9 to 36 VDC battery/solar supply
Power Supply: 100 to 260 VAC, or 9 to 36 VDC battery/solar; 15 to 30 W maximum steady state depending on configuration
Size / Weight: 685 x 330 x 187 mm (27 x 13 x 7-3/8 in) including PM inlet; under 13 kg (28.6 lb) depending on configuration
Regulatory Certifications: EC Directives 2014/30/EU and 2014/35/EU, FCC 47 CFR Part 15, RoHS 3 (EU 2015/863), REACH
Compliance Standards: MCERTS certified for PM10 (AQS 1 PCX), South Coast AQMD Rule 1466 approved (AQS 1 PCX), Configuration-specific — confirm certifications for the exact gas module build before quoting
Intended Use: Construction and remediation air monitoring, fenceline and fugitive dust monitoring, industrial site and landfill monitoring, quarry and mining operations, ports and bulk handling terminals, oil and gas facilities, wastewater treatment plants, and community air quality studies. Common programme types include Construction Environmental Management Plans (CEMP) and Remediation Community Air Monitoring Plans (CAMP)

Manufacturer Resources

Documents

User manuals, safety guides, and technical documentation from the manufacturer:

Videos

No manufacturer videos are currently available for this product. Check back later or contact us for more information.

Ask a Question

Have a question about this product? Fill out the form below and our team will get back to you shortly.

Need Help Choosing the Right Equipment?

Our customer success specialists are here to help you select the perfect equipment for your project